Operations Report Crew 219 Operations Report 14-JAN-2020 Sol: 9 Name of person filing report: Alejandro Perez Non-nominal systems: N/A Generator: Run Hours run: 13 From what time last night: 18:00 To what time this morning: 07:00 List of any additional daytime hours when the generator was run: N/A Solar- SOC% (Before the generator is run at night): 81% 08:30 = 97%; 09:30 = 99%; 10:45 = 95%; 12:15 = 92%; 13:15 = 87%; 14:15 = 86%; 15:15 = 82%; 16:15 = 81%; 17:50 = 100% Diesel Reading - 60% Station Propane Reading- 38% Ethanol Free Gasoline- N/A Water (loft tank) (gal) – 50 Water Meter (units)- 0147688,7 Water (static tank) (gal) – 350 Static to loft Pump used –Yes Water in Green Hab (gal): 161.21 Water in Science Dome (gal): 0 Toilet Tank Emptied –Yes Diemos rover used: Still in the Work shop Hours: Beginning Charge: End Charge: Currently Charging: Sojourner rover used: Assigned to Director Hours: Beginning Charge: End Charge: Currently Charging: Spirit Rover used- Yes Starting Hours: 125.4 Beginning Charge: 100% Ending Hours: 125.6 Ending Charge: 66% Opportunity Rover used: Still in workshop Hours: Beginning Charge: Ending Charge: Currently Charging: Curiosity Rover used: Yes Starting Hours: 131.3 Beginning Charge: 100% Ending Hours: 131.6 Ending Charge: 72% Notes on Rovers: Opportunity and Deimos off-site for maintenance. ATV’s Used: (Honda, 300, 350.1, 350.2, 350.3): No Reason for use: Oil Added? No # hours the ATV’s were used today: Notes on ATVs: Habcar used and why, where? CrewCar used and why, where? In the shop. General Notes and Comments: Summary of the internet: Nominal Summary of Suit and Radios: Checked all suits for battery performance. All one-piece suit batteries have higher voltage than the replacement from the RAM. Summary of Hab: Nominal Summary of Science Dome operations: Temperature averaging 8°C during the day and 0°C at night. Summary of Ram operations: Roof was leaking today. Summary of any observatory issues: Nominal Summary of Health and safety issues: Nominal Questions, concerns, and requests to Mission Support:
Operations Report – January 13th
Operations Report Crew 219 Operations Report 13-JAN-2020 Sol: 8 Name of person filing report: Alejandro Perez Non-nominal systems: N/A Generator: Run Hours run: 1.5 From what time last night: 18:00 To what time this morning: *failure stamp 19:30 List of any additional daytime hours when the generator was run: Start: 06:00 Tuned off: 15:00 Hours run: 9 Solar- SOC% (Before the generator is run at night): 83% 06:30 = 10%; 07:00 = 14%; 08:30 = 22%; 10:00 = 33%; 11:45 = 46%; 12:30 = 51%; 13:30 = 55%; 14:30 = 100%; 15:30 = 98%; 16:30 = 90%; 17:30 = 85%; 18:00 = 83%; 18:30 = 81%; Diesel Reading - 60% Station Propane Reading- 39% Ethanol Free Gasoline- N/A Water (loft tank) (gal) – 50 Water Meter (units)- 0147647,2 Water (static tank) (gal) – 384 Static to loft Pump used –Yes Water in Green Hab (gal): 166.21 Water in Science Dome (gal): 0 Toilet Tank Emptied –Yes Diemos rover used: Still in the Work shop Hours: Beginning Charge: End Charge: Currently Charging: Sojourner rover used: Assigned to Director Hours: Beginning Charge: End Charge: Currently Charging: Spirit Rover used- Yes Starting Hours: 124.9 Beginning Charge: 100% Ending Hours: 125.4 Ending Charge: 27% Opportunity Rover used: Still in workshop Hours: Beginning Charge: Ending Charge: Currently Charging: Curiosity Rover used: Yes Starting Hours: 130.8 Beginning Charge: 100% Ending Hours: 131.3 Ending Charge: 38% Notes on Rovers: Opportunity and Deimos off-site for maintenance. ATV’s Used: (Honda, 300, 350.1, 350.2, 350.3): No Reason for use: Oil Added? No # hours the ATV’s were used today: Notes on ATVs: Habcar used and why, where? CrewCar used and why, where? General Notes and Comments: Summary of the internet: Nominal Summary of Suit and Radios: Nominal Summary of Hab: generator failed due to underspeed issue Summary of Science Dome operations: Temperatures are hovering around 4 °C during the day and 0 °C during the night. Summary of Ram operations: Power converter began a high-pitched whining noise during the day. Outpost and CO assessed the problem. Outpost advised to include it in the notes of the operation report. Summary of any observatory issues: Nominal Summary of Health and safety issues: See HSO report Questions, concerns, and requests to Mission Support: None.
Operations Report – January 13th
Operations Report Crew 219 Operations Report 13-JAN-2020 Sol: 8 Name of person filing report: Alejandro Perez Non-nominal systems: N/A Generator: Run Hours run: 1.5 From what time last night: 18:00 To what time this morning: *failure stamp 19:30 List of any additional daytime hours when the generator was run: Start: 06:00 Tuned off: 15:00 Hours run: 9 Solar- SOC% (Before the generator is run at night): 83% 06:30 = 10%; 07:00 = 14%; 08:30 = 22%; 10:00 = 33%; 11:45 = 46%; 12:30 = 51%; 13:30 = 55%; 14:30 = 100%; 15:30 = 98%; 16:30 = 90%; 17:30 = 85%; 18:00 = 83%; 18:30 = 81%; Diesel Reading - 60% Station Propane Reading- 39% Ethanol Free Gasoline- N/A Water (loft tank) (gal) – 50 Water Meter (units)- 0147647,2 Water (static tank) (gal) – 384 Static to loft Pump used –Yes Water in Green Hab (gal): 166.21 Water in Science Dome (gal): 0 Toilet Tank Emptied –Yes Diemos rover used: Still in the Work shop Hours: Beginning Charge: End Charge: Currently Charging: Sojourner rover used: Assigned to Director Hours: Beginning Charge: End Charge: Currently Charging: Spirit Rover used- Yes Starting Hours: 124.9 Beginning Charge: 100% Ending Hours: 125.4 Ending Charge: 27% Opportunity Rover used: Still in workshop Hours: Beginning Charge: Ending Charge: Currently Charging: Curiosity Rover used: Yes Starting Hours: 130.8 Beginning Charge: 100% Ending Hours: 131.3 Ending Charge: 38% Notes on Rovers: Opportunity and Deimos off-site for maintenance. ATV’s Used: (Honda, 300, 350.1, 350.2, 350.3): No Reason for use: Oil Added? No # hours the ATV’s were used today: Notes on ATVs: Habcar used and why, where? CrewCar used and why, where? General Notes and Comments: Summary of the internet: Nominal Summary of Suit and Radios: Nominal Summary of Hab: Generator had a power malfunction causing no charge with the engine running. SOC became under leveled before 06:00 and safety mode was initiated. Summary of Science Dome operations: Temperatures are hovering around 4 °C during the day and 0 °C during the night. Summary of Ram operations: Power converter began a high-pitched whining noise during the day. Outpost and CO assessed the problem. Outpost advised to include it in the notes of the operation report. Summary of any observatory issues: Nominal Summary of Health and safety issues: See HSO report Questions, concerns, and requests to Mission Support: None.
Operations Report – January 12th
Operations Report
Crew 219 Operations Report 12-JAN-2020
Sol: 7
Name of person filing report: Alejandro Perez
Non-nominal systems: N/A
Generator: Run
Hours run: 17
From what time last night: 15:00
To what time this morning: 08:00
List of any additional daytime hours when the generator was run: N/A
Solar- SOC% (Before the generator is run at night): 82%
09:40 = 94%; 11:00 = 90%; 11:50 = 88%; 12:55 = 100%; 14:10 = 99%;
15:10 = 97%; 16:15 = 94%; 17:05 = 90%; 18:15 = 82%
Diesel Reading – 60%
Station Propane Reading- 40%
Ethanol Free Gasoline- N/A
Water (loft tank) (gal) – 50
Water Meter (units)- 0147603,1
Water (static tank) (gal) – 411
Static to loft Pump used –Yes
Water in Green Hab (gal): 174.86
Water in Science Dome (gal): 0
Toilet Tank Emptied –No
Diemos rover used: Still in the Work shop
Hours:
Beginning Charge:
End Charge:
Currently Charging:
Sojourner rover used: Yes, by Outpost
Hours:
Beginning Charge:100 %
End Charge: 21%
Currently Charging: Yes
Spirit Rover used- No
Starting Hours:
Beginning Charge:
Ending Hours:
Ending Charge:
Opportunity Rover used: Still in workshop
Hours:
Beginning Charge:
Ending Charge:
Currently Charging:
Curiosity Rover used: Yes, by Outpost
Starting Hours:
Beginning Charge: 100%
Ending Hours: 31%
Ending Charge: Yes
Notes on Rovers: Opportunity and Deimos off-site for maintenance.
ATV’s Used: (Honda, 300, 350.1, 350.2, 350.3): No
Reason for use:
Oil Added? No
# hours the ATV’s were used today:
Notes on ATVs:
Habcar used and why, where?
CrewCar used and why, where?
General Notes and Comments:
Summary of the internet: Nominal
Summary of Suit and Radios: Nominal
Summary of Hab: SOS’s were delivered. Repair to loft tank feedline is
working properly, however, the joint connecting the pipe going into
the loft tank is still leaking even with the new Teflon tape added.
Summary of Science Dome operations: Temperatures are hovering around 7
°C during the day.
Summary of Ram operations: Nominal
Summary of any observatory issues: Nominal
Summary of Health and safety issues: Nominal
Questions, concerns, and requests to Mission Support: ¾ in. M-M metal
threaded coupling for feedline pipe.
Operations Report Jan 11
Crew 219 Operations Report 11-JAN-2020
Sol: 6
Name of person filing report: Alejandro Perez
Non-nominal systems: N/A
Generator: Run
Hours run: 14.5
From what time last night: 17:00
To what time this morning: 07:30
List of any additional daytime hours when the generator was run: N/A
Solar- SOC% (Before the generator is run at night): 77%
08:40 = 96%; 09:30 = 94%; 10:20 = 92%; 11:00 = 90%; 11:30= 89%; 12:00=
89%; 12:30= 88%; 13:00 = 85%; 13:30= 85%; 15:00= 82%; 16:00= 80%;
17:00= 77%
Diesel Reading – 65%
Station Propane Reading- 45%
Ethanol Free Gasoline- N/A
Water (loft tank) (gal) – 50
Water Meter (units)- 0147567,5
Water (static tank) (gal) – 444
Static to loft Pump used – Yes
Water in Green Hab (gal): 179.45
Water in Science Dome (gal): 0
Toilet Tank Emptied – Yes
Diemos rover used: Still in the Work shop
Hours:
Beginning Charge:
End Charge:
Currently Charging:
Sojourner rover used: Assigned to Director
Hours:
Beginning Charge:
End Charge:
Currently Charging:
Spirit Rover used- Yes
Starting Hours: 124.5, 124.5
Beginning Charge: 100%, 100%
Ending Hours: 124.5, 124.9
Ending Charge: 23%, 47%
Opportunity Rover used: Still in workshop
Hours:
Beginning Charge:
Ending Charge:
Currently Charging:
Curiosity Rover used: Yes
Starting Hours: 129.9
Beginning Charge: 100%
Ending Hours: 130.3
Ending Charge: 39%
Notes on Rovers: Opportunity and Deimos off-site for maintenance.
ATV’s Used: (Honda, 300, 350.1, 350.2, 350.3): No
Reason for use:
Oil Added? No
# hours the ATV’s were used today:
Notes on ATVs:
Habcar used and why, where?
CrewCar used and why, where?
General Notes and Comments:
Summary of the internet: Nominal
Summary of Suit and Radios: Suit #5 was tested today and worked properly.
Summary of Hab: Air filter for Heater has been replaced with a Clean one. New Teflon tape was used on the Loft tank feedline.
Summary of Science Dome operations: Temperatures are hovering around 7°C during the day.
Summary of Ram operations: Nominal
Summary of any observatory issues: Nominal
Summary of Health and safety issues: Nominal
Questions, concerns, and requests to Mission Support: Metal dish scrubber and a brush to wash dishes for pots and pans.
Operations Report – January 10th
Operations Report
Crew 219 Operations Report 10-JAN-2020
Sol: 5
Name of person filing report: Alejandro Perez
Non-nominal systems: N/A
Generator: Run
Hours run: 14
From what time last night: 17:00
To what time this morning: 07:00
List of any additional daytime hours when the generator was run: N/A
Solar- SOC% (Before the generator is run at night): 84%
10:30 =100%, 11:00 =99%, 11:30 = 98%, 12:00 =97%, 12:30= 96%, 13:00 =
95%, 13:30 = 93%, 14:00 = 91%, 14:30 = 90%, 15:00 = 89%, 15:30 = 88%,
16:00 = 87%, 16:30 = 87%, 17:00 = 84%
Diesel Reading – 70%
Station Propane Reading- 45%
Ethanol Free Gasoline- N/A
Water (loft tank) (gal) – 50
Water Meter (units)- 0147538,3
Water (static tank) (gal) – 468
Static to loft Pump used – Yes
Water in Green Hab (gal): 188.65
Water in Science Dome (gal): 0
Toilet Tank Emptied – No
Diemos rover used: Still in the Work shop
Hours:
Beginning Charge:
End Charge:
Currently Charging:
Sojourner rover used: Assigned to Director
Hours:
Beginning Charge:
End Charge:
Currently Charging:
Spirit Rover used- No
Starting Hours:
Beginning Charge:
Ending Hours:
Ending Charge:
Opportunity Rover used: Still in workshop
Hours:
Beginning Charge:
Ending Charge:
Currently Charging:
Curiosity Rover used: No
Starting Hours:
Beginning Charge:
Ending Hours:
Ending Charge:
Notes on Rovers: Opportunity and Deimos off-site for maintenance.
ATV’s Used: (Honda, 300, 350.1, 350.2, 350.3): No
Reason for use:
Oil Added? No
# hours the ATV’s were used today:
Notes on ATVs:
Habcar used and why, where? Used by Outpost Team to go to the storage
room, get water and
supplies for Outpost and Hab.
CrewCar used and why, where? Off-Campus, still on the workshop for repair.
General Notes and Comments:
Summary of the internet: Nominal
Summary of Suit and Radios: Defective radios have been placed inside
the RAM for Outpost evaluation. The repairs for suit #3 was tested on
EVA 10 today and performed perfectly. All two-piece helmets are
missing one O-Ring for their connectors.
Summary of Hab: Pipe froze again today. The heating coil is still
functioning and the pump is still operating properly. The freezing
seems to be in between the exterior wall and the interior wall leading
to the washroom. This was solved using a combined method of warm water
through the feedline, a hair dryer heating the interior. The
thermostat in the was room read lowest temperature at -2.0°C during
the night. Outpost did a repair today to the exterior section of the
pipe. On the 9th, solar panels were inspected for any damage. All the
system and structure are nominal and fully operational. Heat tape for
the pipelines from the static tank to the Hab is being rearranged in
order to completely fix the frozen pipes issue. Furnace filter was
also changed today. We received Teflon tape, toilet paper, and pipe
insulation.
Summary of Science Dome operations: Temperatures are hovering around 7
°C during the day.
Summary of Ram operations: Nominal
Summary of any observatory issues: Nominal
Summary of Health and safety issues: Nominal
Questions, concerns, and requests to Mission Support: 11 O-Rings (7
replacements and 4 Bench stock) and new transformer for radio charging
unit (input=120VAC 60Hz 9W, Output=9V DC 300 mA)
Operations Report – January 8th
Operations Report Crew 219 Operations Report 08-JAN-2020 Sol: 3 Name of person filing report: Alejandro Perez Non-nominal systems: N/A Generator: Run Hours run: 14 From what time last night: 17:00 To what time this morning: 07:00 List of any additional daytime hours when the generator was run: N/A Solar- SOC% (Before the generator is run at night): 59% Diesel Reading - 73% Station Propane Reading- 51% Ethanol Free Gasoline- N/A Water (loft tank) (gal) – 50 Water Meter (units)- 0147473,1 Water (static tank) (gal) – 506 Static to loft Pump used – Yes Water in Green Hab (gal): 200.02 Water in Science Dome (gal): 0 Toilet Tank Emptied – Yes Diemos rover used: Still in the Work shop Hours: Beginning Charge: End Charge: Currently Charging: Sojourner rover used: Assigned to Director Hours: Beginning Charge: End Charge: Currently Charging: Spirit Rover used- Yes EVA #6 Starting Hours: 123.5 Beginning Charge: 100% Ending Hours: 123.7 Ending Charge: 68% Opportunity Rover used: Still in workshop Hours: Beginning Charge: Ending Charge: Currently Charging: Curiosity Rover used: Yes EVA #6 Starting Hours: 129.3 Beginning Charge: 100% Ending Hours: 129.5 Ending Charge: 70% Notes on Rovers: Opportunity and Deimos off-site for maintenance. ATV’s Used: (Honda, 300, 350.1, 350.2, 350.3): No Reason for use: Oil Added? No # hours the ATV’s were used today: Notes on ATVs: Habcar used and why, where? Used by Outpost team to take Crew car to the Work shop, refilled with gas. CrewCar used and why, where? Crew car was brought to the workshop, is off site, and was refilled. General Notes and Comments: Summary of the internet: Nominal Summary of Suit and Radios: A two- piece helmet had vents that were stuck aiming downward providing no defogging during EVA #5. The vents freely rotate within this helmet and cannot be secured. Transformer for Charging unit 4 is giving very high amperage and voltage exceeding the limits for the radio batteries. This transformer has been marked not to be used. Also, during EVA there was a window where EVA radios were giving a persistent static. The radios are being tested and troubleshot for any deficiencies in connectivity, battery performance, and individual radio issues. Summary of Hab: Pipe froze again today. The heating coil is still functioning and the pump is still operating properly. The freezing seems to be in between the exterior wall and the interior wall leading to the washroom. This was solved using a combined method of warm water through the feedline, a hair dryer heating the interior and exterior pipe through the wall. Summary of Science Dome operations: Nominal Summary of Ram operations: Nominal Summary of any observatory issues: Nominal Summary of Health and safety issues: Nominal Questions, concerns, and requests to Mission Support: Requesting for Teflon tape for the loft tank feedline and new insulation for the Static tank to Loft tank pipe.
Operations Report – January 07th
Crew 219 Operations Report 07-JAN-2020
Sol: 2
Name of person filing report: Alejandro Luis Perez
Non-nominal systems: N/A
Generator: Run
Hours run: 13.5
From what time last night: 17:00
To what time this morning: 06:30
List of any additional daytime hours when the generator was run: N/A
Solar- SOC% (Before the generator is run at night): 49%
Diesel Reading – 74%
Station Propane Reading- 52%
Ethanol Free Gasoline- N/A
Water (loft tank) (gal) – 50
Water Meter (units)- 0147447,5
Water (static tank) (gal) – 526
Static to loft Pump used – Yes
Water in Green Hab (gal): 204.88
Water in Science Dome (gal): 0
Toilet Tank Emptied – No
Diemos rover used: Still in the Work shop
Hours:
Beginning Charge:
End Charge:
Currently Charging:
Sojourner rover used: Assigned to Director
Hours:
Beginning Charge:
End Charge:
Currently Charging:
Spirit Rover used- Yes
EVA #4
Starting Hours: 123.3
Beginning Charge: 100%
Ending Hours: 123.5
Ending Charge: 67%
Opportunity Rover used: Still in workshop
Hours:
Beginning Charge:
Ending Charge:
Currently Charging:
Curiosity Rover used: Yes
EVA #4
Starting Hours: 129.1
Beginning Charge: 100%
Ending Hours: 129.3
Ending Charge: 71 %
Notes on Rovers: Opportunity and Deimos off-site for maintenance.
ATV’s Used: (Honda, 300, 350.1, 350.2, 350.3): No
Reason for use:
Oil Added? No
# hours the ATV’s were used today:
Notes on ATVs:
Habcar used and why, where? Yes, used to fill static tank by Outpost.
CrewCar used and why, where? No
General Notes and Comments:
Summary of the internet: Nominal
Summary of Suit and Radios: Suits #1 and #7 are fully functional, weak air flow from yesterday’s EVA could have been from the low temperatures. Suit #5 does not work. The multimeter was used to see where power is not being transmitted and found that all connection from battery to circuit board are good. However, there is no power being delivered to the fans. Suit #3 has weak air flow coming from both fans even on full power. Battery testing on Suit #3 will be conducted tomorrow. Red Helmet was fixed by securing the head pad back in place using cable ties. The connector has been placed on the helmet missing a connector, however, there is no gasket for this connector. Also, one of the chargers got disconnected from its connector. This was fixed by soldering the cable back to the connector and this charger is working again.
Summary of Hab: Heating strip is working to keep the pipe from the static tank to loft tank from freezing. However, the insulation looks to be falling apart from the cold temperatures. Also, the cable obstructing the fire escape window has been removed and placed inside the RAM.
Summary of Science Dome operations: Nominal
Summary of Ram operations: Nominal
Summary of any observatory issues: Nominal
Summary of Health and safety issues: Nominal
Questions, concerns, and requests to Mission Support: Requesting Teflon tape for the loft tank feedline, new insulation for the Static tank to Loft tank pipe, and gasket for one of the 2 piece helmet connectors.
Operations Report – January 06th
Operations Report
Crew 219 Operations Report 06-JAN-2020
Sol: 1
Name of person filing report: Alejandro Luis Perez
Non-nominal systems: N/A
Generator: Run
Hours run: 14
From what time last night: 17:30
To what time this morning: 07:30
List of any additional daytime hours when the generator was run: N/A
Solar- SOC% (Before the generator is run at night): 49%
Diesel Reading – 73%
Station Propane Reading- 50%
Ethanol Free Gasoline- N/A
Water (loft tank) (gal) – 55
Water Meter (units)- 0147407,8
Water (static tank) (gal) – 513
Static to loft Pump used – Yes
Water in Green Hab (gal): 213.25
Water in Science Dome (gal): 0
Toilet Tank Emptied – Yes
Diemos rover used: Still in the Work shop
Hours:
Beginning Charge:
End Charge:
Currently Charging:
Sojourner rover used: Assigned to Director
Hours:
Beginning Charge:
End Charge:
Currently Charging:
Spirit Rover used- Yes
EVA #1
Hours: 123.1
Beginning Charge: 100%
Ending Charge: 88%
EVA #2
Hours:123.3
Beginning Charge: 100%
Ending Charge: 92%
Currently Charging: Yes
Opportunity Rover used: Still in workshop
Hours:
Beginning Charge:
Ending Charge:
Currently Charging:
Curiosity Rover used: Yes
EVA #1 and 2
Hours: 129.0
Beginning Charge: 100%
Ending Charge: 91%
EVA #2
Hours: 129.1
Beginning Charge: 100%
Ending Charge: 95%
Currently Charging: Yes
Notes on Rovers: Opportunity and Deimos off-site for maintenance.
ATV’s Used: (Honda, 300, 350.1, 350.2, 350.3): Yes, Outpost used ATV #1, and #3
Reason for use: Used for maintenance.
Oil Added? No
# hours the ATV’s were used today: 0.5
Notes on ATVs: Honda battery was not responsive, it needed to be jumped in order for it to turn on. This is the third occasion.
Habcar used and why, where? Used by the Outpost team to storage and Post Office.
CrewCar used and why, where? No
General Notes and Comments: Spare heat tape being kept in the RAM. The extension that is connected to the current heat tape has been relocated to the inner plugs in the lower deck. Also, Astronomer used the rest of the Orange marking tape for his experiment.
Summary of the internet: limited intermittent dysconnectivity
Summary of Suit and Radios: Suits #5 and Suits #1 do not have air flow. One headset that was not operating.
Summary of Hab: Followed instructions given by Director Rupert for flushing the toilet. Filled and emptied the toilet 2 times and added digester. Now operating on normal toilet procedures. See attached requested photos below regarding the black seal of the toilet. Also, the feedline to the loft tank is still leaking when the pump is turned on. Teflon tape would help improve the seal.
Summary of Science Dome operations: Nominal
Summary of Ram operations: Nominal
Summary of any observatory issues: Nominal
Summary of Health and safety issues: See HSO report
Questions, concerns, and requests to Mission Support: Request for more Orange Marking Tape and Teflon tape
Operations Report – January 5th
Operations Report
Crew 219 Operations Report 05-01-2020
Sol: 0
Name of person filing report: Alejandro Luis Perez
Non-nominal systems: N/A
Generator : Run
Hours run : 13
From what time last night: 18:00
To what time this morning: 07:00
List of any additional daytime hours when the generator was run: N/A
Solar- SOC% (Before generator is run at night): 67%
Diesel Reading – 73%
Station Propane Reading- 57%
Ethanol Free Gasoline- N/A
Water (loft tank) (gal) – 55
Water Meter (units)- 0147363,4
Water (static Tank) (gal) – 550
Static to loft Pump used – Yes
Water in Green Hab (gal): 150 and still filling before the beginning
of the mission
Water in Science Dome (gal): 0
Toilet Tank Emptied – Yes
Diemos rover used: Still in the Workshop
Hours:
Beginning Charge:
End Charge:
Currently Charging:
Sojourner rover used: Assigned to Director
Hours:
Beginning Charge:
End Charge:
Currently Charging:
Spirit Rover used- Yes
Hours: 122.9
Beginning Charge: 100%
End Charge: 65%
Currently Charging: Yes
Opportunity Rover used: Still in the workshop
Hours:
Beginning Charge:
Ending Charge:
Currently Charging:
Curiosity Rover used: Yes
Hours: 128.3
Beginning Charge: 100%
Ending Charge: 70%
Currently Charging: Yes
Notes on Rovers: Opportunity and Deimos off-site for maintenance.
ATV’s Used: (Honda, 300, 350.1, 350.2, 350.3): No
Reason for use: N/A
Oil Added? No
# hours the ATV’s were used today: 0
Notes on ATVs: N/A
Habcar used and why, where? Yes, to fill static tank and Greenhab tank
from hollow mountain Gas station
CrewCar used and why, where? Yes, to bring Crew 218 back to grand
junction. Currently in Grand junction.
General Notes and Comments: installation of the lower deck heater, but
that it won’t be operational until positioned on the right location
Summary of the internet: Not Responsive
Summary of Suit and Radios: Radio # 8 was not receiving signal. There
are currently 2 suit helmets that need repair. One has a broken head
pad panel that does not stay in place. The other is missing the
right-side connection piece for air.
Summary of Hab: The pipe connecting static tank to loft tank has to be
defrosted by using a combination of Hairdryer to the outside pipe,
warm water poured into the feed line, and re-taping the insulation
around the outside pipe.
Summary of Science Dome operations: Adjusted latching mechanism on
Science Dome door. The door now latches closed.
Summary of Ram operations: Nominal
Summary of any observatory issues: Previous Crew had replaced both the
batteries and a new Fire alarm unit. However, the alarm was
consistently going off. According to the unit the system does not
operate in conditions under 40 °F. And there is no Co alarm in there
as well.
Summary of Health and safety issues: Smoke and Co alarm have been
replaced in Greenhab. All ABC fire extinguisher are out of date, the
observatory does not have a fire extinguisher, BC fire extinguisher in
RAM has no date and is broken and three good aerosol fire
extinguishers.
Questions, concerns, and requests to Mission Support: Light bulbs
missing in 4 crew rooms, Max watts is 13.




You must be logged in to post a comment.