Report title: Operations Report
Crew #: 333
Position: Executive Officer / Crew Engineer
Report prepared by: Antoine Dubois
Date: 02-04-2026
Sol: 4

Non-nominal systems: Pressurised tunnels & suit charger, Comms kit #4

Notes on non-nominal systems:

  • Pressurised tunnels: We repaired the pressurised tunnel using 10 zip ties due to the high winds.

  • Suit charger: We hadn’t noticed, but one of the chargers was broken (probably before we arrived) (See pictures below). We replaced it with a new one. Could we fix it with glue? Is that possible, or is it unsafe?

  • All the joints of the comms kit #4 headset were resoldered. The problem has been solved.

ROVERS

Spirit rover used: EVA #6

Hours: 301.7
Beginning charge: 100%
Ending charge: 38%
Currently charging: Yes

Opportunity rover used: No

Hours: /
Beginning charge: /
Ending charge: /
Currently charging: No

Curiosity rover used: No

Hours: /
Beginning charge: /
Ending charge: /
Currently charging: No

Perseverance rover used: EVA #6

Hours: 402.6
Beginning charge: 100%
Ending charge: 26%
Currently charging: Yes

General notes on rovers: None

Summary of Hab operations:

Water Use: 13.57 gallons
Main tank level: 287 gallons
Main water tank pipe heater (ON or OFF): OFF
Main water tank heater (ON or OFF): YES
Toilet tank emptied (NO or YES): NO

Summary of internet: Connection used for research, listening to music, sending reports and watching Night at the Museum 2.

Summary of suits and radios:

  • Matthias De Groote, Greenhab Officer: Suits and radio 5

  • Marie, Commander: Suits and radio 1

  • Antoine, Executive officer: Suits and radio 2 (headset 3)

Summary of GreenHab operations:

Water use: 2.65 gallons
Heater (ON or OFF): ON, 70 F°
Supplemental light (hours of operation): 7:30 pm to 11:30 pm
Harvest (name, weight in grams): N/A

Summary of ScienceDome operations: We used Science Dome for Joanna’s experiment with Tap Strap.

Dual split (Heat or AC, On or Off or Automatic): AC, Automatic

Summary of RAM operations: Usage of solder material for preparation of comms kit #4, also the multimeter and some pliers were used.

Summary of any observatory issues: None

Summary of health and safety issues: None

Questions, concerns and requests to Mission Support:

  • Suit charger: Could we fix it with glue? Is that possible, or is it unsafe?

  • Trash is in the RAM